Model 4097A Cable & Connector Testing System Performance Specifications:

CONTINUITY / CONTACT RESISTANCE

Up to 160 Wires (320 Terminations); Resistance
Measurements: 0.01 Ohms to 4000 Ohm
Contact Resistance: 0.004 – 16 Ohms

INSULATION RESISTANCE

5 - 100,000 MΩ, 2%
0 - 1500 VDC Test Voltage,
0.1% 0.1 - 650 Second Programmable Dwell
100 G - 500 G Ω, 5%
0 - 2500VDC Test Voltage, 0.1%

DIELECTRIC WITHSTANDING VOLTAGE

DC:
0 - 1500 VDC Test Voltage, 0.1%
0 - 1000uA Fail Current, 2%
0.1 - 650 Second Programmable Dwell
0 - 2500 VDC Test Voltage, 0.1%
AC::
0 - 1800 VAC, 60Hz, 2%
0 - 2000 uA Fail Current, 2%
0.1 - 650 Second Programmable Dwell
Ramp Options: 500 VAC/sec or 200 VAC/cycle
0 - 2300 VAC Test Voltage, 2%

CAPACITANCE

1pF - 1uF: 1% typical; 2% or 2pF Max
whichever is greater at 1KHz
Test Capacitance at DC Bias Voltages 0-750VDC
DISSIPATION FACTOR:
0 - 100%, 0.25%
SHORTED PIN TEST
Verify Intentionally Shorted Pins either to ground or to another pin

GROUND RING TEST
Verify Presence of Ground Ring
ZENER DIODE / MOV
0 - 750 VDC Test Voltage, Bipolar
1 - 10 mA test current
4.8 - 750 VDC Breakdown Voltage,
0.5% or 0.1V, whichever is greater
Selectable Reverse Leakage Limits
1 nA - 10,000nA, 1uA - 1000uA

AC POWER REQUIREMENTS

105 - 125 VAC, 50/60 Hz
350 mA AC Input Current
Europe 230 VAC, 50Hz

Ideal for ‘D’ Subminiature, Micro ‘D’ Cables, ARINC and Other Types of Cable Harnesses
Dimensions: 14" W x 14" H x 19" D; Weight = 45 lbs. / 20.4 kg